Yes, you can store a rotary air compressor empty. In fact, storing it empty is usually the best way but only if it is prepared properly.
Many experts working with industrial air systems recommend draining the tank every time when the compressor is shut down. Some people leave air compressors pressurized overnight if they plan to use them again soon. This is generally fine for short periods as long as you do not forget.
Risks of storing a rotary compressor without prep
Moisture causes internal rust
Air compressors always pull in moisture along with air. That moisture turns into liquid and settles in the bottom of the tank and piping.
If the machine is turned off without draining this moisture, the water stays inside. Then, it creates rust inside the tank. Over time, that rust weakens the tank walls and makes it unsafe.
Used oil becomes contaminated
Some types of air compressors use oil to lubricate internal moving parts. During use, oil picks up water, dirt and metal particles. If this oil stays in the machine during storage, it continues to break down.
This dirty oil thickens into sludge. That sludge clogs filters, damages seals and internal surfaces to cause wear faster. It is important to change this oil or replace it with preservative oil, if the compressor will not be used for some time.
Bearings and rotors can seize
The bearings and rotors inside rotary screw compressors need to be lubricated. Without movement or oil flow, parts can seize or develop “flat spots” where metal touches metal. This can cause grinding or failure when you restart the compressor.
Standing moisture encourages microbial growth
When moisture is left in the air system, it creates conditions where microbes can grow inside the hoses, pipes, and filters. When the machine runs again, the bacteria can clog or damage internal components. This kind of contamination can affect air quality and shorten the life of components.
How to store rotary screw air compressor safely
Large systems even use auto drain setups. If your compressor does not have an auto drain system, then follow the steps below.
Step 1: Remove all moisture
Run the compressor briefly. Let it build enough pressure to blow out water from internal lines. Then:
- Open all drain valves: on the air tank, filters and aftercoolers
- Let them hiss until only air comes out
- Leave the valves open during storage
This allows trapped moisture to escape and prevents it from building up again. If you skip this, rust is guaranteed. Draining takes two minutes and should be done every time when you shut down the machine. This step is necessary for small home compressors.
Step 2: Vent the System
- Close the main outlet valve.
- Open all other vents or quick connect couplers.
- Make sure there is no air pressure trapped inside.
This prevents pressure buildup and reduces the load on valves and seals. Do not store the compressor with sealed lines. Always allow the system to stay unpressurized.
Step 3: Handle the Oil Properly
Oil care depends on how long you plan to store the compressor.
For short term storage (a few weeks to 2 months):
- Turn on the compressor to warm up the oil.
- Turn it off and immediately drain the oil while warm. This removes moisture and dirt.
- Refill with clean, unused oil to coat internal parts.
For long term storage (3 months or more):
- Drain the oil after warming it up.
- Add special storage oil or preservative oil as recommended in the manual.
Do not leave the compressor dry. Some internal parts need to stay coated with oil to avoid damage during long idle periods.
Step 4: Cover openings to block dust
Now protect your compressor from dust, bugs and debris.
- Cover air intakes, vents and open drain ports with cloth or paper towels
- Do not seal the openings with plastic bags or airtight wraps.
The goal is to block contamination while air needs to circulate inside during storage. Sealing it too tightly will trap moisture and raise humidity levels inside the system.
Read more about how to control moisture in compressed air systems
Best storage environment for rotary compressors
Where you store your compressor is just as important as how you store it.
- Keep the compressor in a space that is dry, well ventilated and protected from weather and temperature changes.
- Avoid garages, sheds or basements that have high humidity or large temperature swings. These cause condensation.
- Do not place the compressor directly on a concrete or wet floor. Use wood blocks or pallets to lift it off the ground.
- Avoid areas with water leaks, damp floors, or poor ventilation.
Cover the compressor with a cloth sheet or breathable tarp. This keeps off dust without trapping moisture. Do not use plastic or waterproof covers that seal in humidity.
Extra tips for Long term storage (6+ months)
If you are going to store compressor for more than six months, then do this:
- If the pump shaft is accessible and safe to turn.
- Rotate it by hand once a month.
- This helps keep oil distributed and bearings protected.
Only do this if the machine design makes it safe to access and rotate.
Storage Mistakes to Avoid
- Do not leave the tank pressurized.
- Do not leave used or dirty oil inside.
- Do not seal openings with airtight materials.
- Do not store the compressor outside or in wet areas.
- Do not forget to open drain valves.
- Do not assume the machine is protected just because it’s turned off.
Even a few days of lazy storage can cost a lot of damage. If you are storing for any length of time, get it right the first time.
Final notes
Every compressor is different. Always read your compressor’s manual for shutdown instructions specific to your model.
Storage becomes even more important in small compressors because they can collect large amounts of water over time. For example, running a 20HP industrial compressor, 110 PSI, approximately 70-80 CFM will generate about 10-12 gallons of water per day (this depends on the actual relative humidity of the intake air).
Assuming a 120 gallon receiver tank and a 50% duty cycle, you would end up with roughly 150 to 180 gallons of water sloshing around in the course of a month, if you did not drain.
So, if your compressor is used frequently, a few minutes of care during shutdown prevents expensive repairs and long term damage.